Android software burning failed, daemon not running

Android software burning failed, daemon not running


The following information is displayed after the customer uses a Win10 computer, correctly links the USB cable, runs the Android APP and burns the BAT file.

Cause: The customer's system does not support Chinese, so the Chinese naming of the burn software package we provided cannot work correctly.

Solution: Let the customer create a new folder in the root directory of the disk, name it with letters, copy all files in the software package to the new folder, and then run APP to burn bat.

Corrective action: Write software packages using English names.


    • Related Articles

    • 安卓软件烧写失败,daemon not running-中英文版

      客户使用Win10计算机,已正确链接USB线,运行安卓APP烧写bat文件后显示如下信息: 原因:客户的系统不支持中文,我们提供的烧写软件包中文命名无法正确运行 解决:让客户在磁盘根目录下建立新文件夹,以字母命名,拷贝软件包内所有文件到新建的文件夹内,再运行APP烧写bat即可 纠正措施:烧写软件包使用英文命名 Android software burning failed, daemon not running The following information is displayed ...
    • Lasermach Software Upgrade steps

           1、Prepare ARM board programming        Computer install “One-click install Android driver”first.       Connect the Android cable to ARM board and computer.           Press and hold the PWR button on the  ARM board and power on system same time. ...
    • Renuva Software Upgrade steps

      Tips: Scope of application: Engineer Applicable grade: Professional Service tools:  Phillips screwdriver、 Inner Hexagon spanner ​ I. ARM Board Android line connected with the ARM Board and computer Hold down the PWR key on the ARM Board and power up. ...
    • Mainboard and Handpiece software compatibility table

      Handpiece software Mainboard  software   L4-A-1. 0. 006(STM32) L4-A-1. 1.003(GD32) L0-A-1. 0. 129 (STM32) Power on, An E16 alarm occurs after several laser launches Power on, An E16 alarm occurs after several laser launches L0-A-1.0. 133(STM32) 0K ...
    • The fan in the main console stops running in the ready state

      a)  Use a multimeter to check whether the voltage is DC24V between the water quality testing boards P1.2 and J1.3 If not, replace the water quality testing boards. b) Continue to check whether the voltage is DC24V between the water quality testing ...